SPECIFICATIONS
Size . . . . . . . . . . . . . . . .4.0"H x 7.5"W x 10.8"D (10.2 cm x 19.6 cm x 26.2 cm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.8 lbs. (1.7 kg)
Electrical Requirements . . . . . . . . . . . . . .100-240V~, 50/60 Hz or 120V~, 400 Hz
Maximum Power Consumption . . . . . . . . . . . . .65 watts max from AC power source
AutoAdjust CPAP Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20 cmH
Operating Temperature Range . . . . . . . . . . . . . . . . .41°F to 104°F (5°C to 40°C)
Operating Humidity Range . . . . . . . . . . . . . . . . . .0% to 95% RH non-condensing
Operating Atmospheric Conditions . . . . . . . . . . . . . . . . . .Sea level to 9,000 feet
Storage & Transportation Temperature Range. . . .-40°F to 158°F (-40°C to +70°C)
Storage & Transportation Humidity Range. . . . . . . .0% to 95% RH non-condensing
Maximum Limited Pressure . . . . . . . . . . . . . . . . . . . .20 cmH
Sound Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .< 30 dBA
Filter specs . . . . . . . . . . . . . . . . . . . . . . . .Standard Filter > 3.0 micron particles
Max flow rates
83 L/m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .@ 6.5 cmH
134 L/m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .@ 13 cmH
163 L/m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .@ 20 cmH
Pressure Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .± 0.5 cmH
Pressure Swings (cmH
O peak to peak at 500mL tidal volume, sine wave profile)
2
Breaths per minute
@ 6.5 cmH
O
2
@ 13 cmH
O
2
@ 20 cmH
O
2
NOTE–For results of extreme testing of static and dynamic pressure regulation refer to
the Sunrise Medical web site (www.sunrisemedical.com).
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Two-year limited
Equipment classification with respect to protection from electric shock . . . .Class II
Degree of protection from electric shock . . . . . . . . . . . . . . . .Type BF Applied Part
Degree of protection against ingress of liquids . . . . . . . . . . . . . . . . . . . . . .None
Equipment not suitable for use in the presence of a flammable anesthetic mixture
with air or with oxygen or nitrous oxide.
Mode of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Continuous
Clinical Specifications for Digital Outputs
Mask Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 to 25.5 cmH
Patient Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-127 to +127 L/min ± 10 L/min
Leak Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 to +127 L/min ± 10 L/min
Estimated Tidal Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 to 1023 mL
NOTE–Tidal Volume is an estimate. It is provided for trending purposes only.
Oximeter Specifications
Data Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72 hours storage
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 sample every 4 seconds