MODELS
DIMENSIONS cm POWER SUPPLY
FT*-94ET*
40x90x90h
80x90x90h
FT**-98ET*
FT**-916ET*
160x90x90h
40x90x90h
FTC-94ET
FTC-98ET
80x90x90h
40x90x29h
FT*T-94ET*
80x90x29h
FT**T-98ET*
FTCT-94ET
40x90x90h
40x90x29h
FTCT-98ET
L= Smooth hotplate R= Corrugated hotplate
L/R= ½ Smooth +1/2 Corrugated
S= Chromium-plated hotplate
MODELS
DIMENSIONS cm POWER SUPPLY
40x90x90h
FTC-94ET
FTC-98ET
80x90x90h
40x90x90h
FTC-94ET
80x90x90h
FTC-98ET
FTCT-94ET
40x90x90h
40x90x29h
FTCT-98ET
FTCT-94ET
40x90x90h
40x90x29h
FTCT-98ET
The data plate is on the front panel (see diagram in electric connection item) and has all the data necessary for the
connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
GB
TECHNICAL DATA TABLE
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
400V~3N 50/60Hz
TRANSFORMATION
230V~3 50/60Hz
230V~3 50/60Hz
230V~ 50/60Hz
230V~ 50/60Hz
230V~3 50/60Hz
230V~3 50/60Hz
230V~ 50/60Hz
230V~ 50/60Hz
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
IE
MAXIMUM
MAXIMUM
ABSORPTION A
POWER kW
10,87
21,74
21,65 + 21,65
5,1
10,2
10,87
21,74
5,1
10,2
MAXIMUM
MAXIMUM
ABSORPTION A
POWER kW
8,79
17,57
15,22
30,44
8,79
17,57
15,22
30,44
24
POWER SUPPLY
CABLE
(Silicone)
7,5
5x1,5 mm²
15
5x2,5 mm²
30 (15 + 15)
5 x 4 mm² + 5 x 4 mm²
3,5
5x1 mm²
7
5x1,5 mm²
7,5
5x1,5 mm²
15
5x2,5 mm²
3,5
5x1 mm²
7
5x1,5 mm²
POWER SUPPLY
CABLE
(Silicone)
3,5
4x1 mm²
7
4x2,5 mm²
3,5
3x2,5 mm²
7
3x4 mm²
3,5
4x1 mm²
7
4x2,5 mm²
3,5
3x2,5 mm²
7
3x4 mm²