LP Conversion Instructions
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manu-
facturerʼs instructions and all applicable codes and requirements of the authority having jurisdic-
tion. If the information in these instructions is not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property damage, personal injury or loss of life. The
qualified service agency is responsible for the proper installation of this kit. The installation is not
proper and complete until the operation of the converted appliance is checked as specified in the
manufacturerʼs instructions supplied with the kit.
Caution: Before proceeding with the conversion, shut off the gas supply to the appliance prior to
disconnecting the electrical power.
1. Following below instruction to change pressure regulator
from natural gas to LP
A
B
Unscrew the top hat
nut from the regulator
E
F
Upturn threaded pin
Configuration for
and screw pin back
LPG
-19-
C
D
Configuration for
Unscrew the threaded pin
from top hat
natural gas
G
H
Refit the top hat nut
assembly to the regulator
2. Follow the instructions below to change the burner orifices
from Natural Gas to LP
Save these orifices and note their positions for future conversions back to natural gas.
Step 1: Lift off the burner caps and burner heads from the cooktop burner manifold cups.
Step 2: Using a 9/32" or 7mm nut drive, remove the burner orifice from the bottom of the
13200BTU/5800BTU/3000BTU burner manifold cup. And replace with the LP burner nozzles,
then screw up clockwise.
Step 3: Using Phillips screwdriver take off the bracket, then using a 9/32" or 7mm open-end
wrench, remove the burner orifice from the bottom of center burner manifold cup. And replace the
LP burner nozzles.
LP Conversion Instructions
Burner cap
Burner head
Burner cup
Orifice size(mm)
Semi Rapid Burner 0.65
Simmer Burner 0.55
Rapid Burner 0.92
Orifice size
0.7mm
0.6mm
0.7mm
-20-