Complete preparation
1
Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See "Venting Requirements" section.
2
Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3
Run the home power supply cable according to the
National Electrical Code or CSA Standards and local codes
and ordinances. There must be enough ½" conduit and
wires from the fused disconnect (or circuit breaker) box to
make the connection in the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4
Use caulk to seal all openings.
INSTALL RANGE HOOD
1
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
1
2
Mark with a pencil the lower mounting holes location.
3
Uninstall the hood assembly, and drill
holes at marked locations.
4
Hang the range hood again on 2 upper mounting screws.
5
Level the range hood and tighten upper mounting screws.
6
Install 2 - 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
Connect vent system
1
Install transition on top of hood (if removed for shipping)
with 2 - 3.5 x 9.5 mm sheet metal screws.
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1
Fit vent system over the exhaust outlet.
2
Measure from the bottom of the air deflector to the
bottom of the hood outlet. Cut the ductwork at the
measured dimension.
3
4
ELECTRICAL CONNECTION
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
B
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1
2
3
C
" (4.8 mm) pilot
3
1 6
4
A.White wires
B. Black wires
C. UL listed wire connectors
5
6
Roof outlet
Wall
outlet
Seal connection with clamps.
Check that back draft dampers work properly.
Disconnect power.
Remove terminal box cover.
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
B
C
A.
B.
Junction box cover
C.
Junction box cover screws
Run home power supply cable through strain relief, into
terminal box.
B
A
D. Green, Bare or Yellow/Green wires
E. Home power supply
F. UL listed or CSA approved ½" strain
Use UL listed wire connectors and connect black wires
(C) together.
Use UL listed wire connectors and connect white wires (E)
together.
Dimension