15. ErP information
ECMR 142
Refrigerant leakage contributes to climate change. Refrigerant with lower
global warming potential (GWP) would contribute less to global warming than
a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 3. This means that if 1 kg of
this refrigerant fluid would be leaked to the atmosphere, the impact on global
warming would be 3 times higher than 1 kg of CO2 , over a period of 100
years. Never try to interfere with the refrigerant circuit yourself or disassemble
the product yourself and always ask a professional.
16. Energy consumption:
•
1.5 kWh per 60 minutes during cooling
•
1.3 kWh per 60 minutes during heating
Based on standard result tests.
Actual energy consumption will depend on how the appliance is used and where it is
located.
17. This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
18. If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
19. Appliance shall be installed, operated and stored in a room with a floor area larger
than 13 m2.
20. Keep ventilation openings clear of obstruction
21. The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
22. The energy efficiency class of the model.
23. Environment friendly disposal! You can help protect the environment! Please
remember to respect the local regulations: hand in the non-working electrical
equipments to an appropriate waste disposal centre. The packaging material is
recyclable. Dispose of the packaging in an environmentally friendly manner and
make it available for the recyclable material collection-service.
V.1.0
22
BELANGRIJKE VEILIGHEIDSVOORZORGEN
1. Het toestel moet geïnstalleerd worden in overeenstemming
2. Details van het type en het vermogen van de zekeringen
• OPMERKING: Zekeringsparameter van de eenheid is 3,15A
TECHNISCHE DETAILS
Model
EER
Stroomvoorziening
Koelvermogen
Inputstroom koeling
Stroom koeling
Verwarmingscapaciteit
Inputstroom voor verwarming
Verwarmingsstroom
ECMR 142
2.69 WW
220-240 V~/50 Hz
4100 W
1520 W
6.5 A
3300 W
1270 W
4.5 A
23