General
Flav-R-Savor
Humidified Holding and Display Cabinets are
®
shipped with most components installed and ready for
operation. The following installation instructions must be
performed before plugging in and operating the cabinet.
WARNING
ELECTRIC SHOCK HAzARD: Unit is not weatherproof.
Locate unit indoors where the ambient air temperature is a
minimum of 21°C (70°F).
FIRE HAzARD: Locate unit a minimum of 25 mm (1") from
combustible walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
CAUTION
Locate unit at the proper counter height in an area that is
convenient for use. The location should be level to prevent
the unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
The National Sanitation Foundation (NSF) requires that
units over 914 mm (36") in width or weighing more than
36 kg (80 lbs.) either be sealed to or raised above the
installation surface. If unit cannot be sealed at the point of
use, 102 mm (4") legs are available to allow for proper
cleaning access below unit.
Transport unit in upright position only. Before moving or
tipping unit, secure all glass surfaces with tape and drain
water from water reservoir. Failure to do so may result in
damage to unit or personal injury.
1. Remove the unit from the carton. Two people are required
for this step.
2. Remove the information packet.
3. Remove tape and protective packaging from all surfaces of
the unit.
• Floor Sheet — The stainless steel floor in all cabinets is
protected during shipping with a sheet of corrugated
cardboard. This protection must be removed prior to
cabinet operation.
• Display Rack — The display rack has packing material
and cardboard attached for protection during shipping.
This protection must be removed prior to cabinet
operation.
• Legs — The cabinets are shipped with four rubber feet
attached to the bottom of the unit. For cabinets with the
optional 102 mm (4") adjustable legs, see the OPTIONS
aND aCCESSORIES section for installation instructions.
NOTE: If installing 102 mm (4") legs, do not remove glass
protection until leg installation is complete.
Form No. FSDCEM1-0916
• Glass Side Panels — The cabinets have tempered glass
side panels that are protected during shipping using
foam sheets along the glass edges and tape to hold the
panels securely. The sheets and tape must be removed
prior to cabinet operation.
NOTE: Any impact to the tempered glass can cause breakage.
To remove a glass panel, grasp the panel firmly from
inside and outside of the cabinet. Lift up and out of the
bottom channel, then carefully lower the glass panel until
it clears the upper channel.
To reinstall, position the glass panel top edge under the
cabinet lip. Raise the panel until it clears the bottom
channel, then carefully lower the panel until it rests in the
bottom channel.
4. Place the unit in the desired location. Two people are
required for this step.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 21°C
(70°F). avoid areas that may be subject to active air
movements or currents (i.e., near exterior doors, exhaust
fans/hoods, and air conditioning ducts).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
• Make sure all the feet on the bottom of the unit are
positioned securely on the countertop.
Digital
Temperature
Controller
Fill Cup
Access Door
Glass Side
Panel
7
INSTALLATION
POWER ON/OFF
(I/O) switch
Air Heating
System
Components
Display
Rack