Installation and assembly
Units represented in this manual are intended for indoor use only. Be sure the location chosen has a
floor strong enough to support the total weight of the unit and contents. For the most efficient operation,
be sure to provide good air circulation inside and outside of the unit.
INSIDE CABINET
The first cleaning must be made when you unpack the unit and before switching it on. Clean it with
water and a mild detergent. When it is clean and dry, insert the accessories in the appropriate places,
for the best use of the user.
OUTSIDE CABINET
Be sure the unit has good air circulation around it. Avoid hot corners and locations near stoves and
ovens. It is recommended the unit be installed no closer than 2" from any wall. The place where the
refrigerator is placed must be open and clean, avoiding that de fan of the condensing unit absorbs
materials which are deposited then into the condenser blades and coil, which can produce failures.
The unit should not be installed under ambient temperatures higher than 100 °F.
If the relative humidity is higher than 60 %, the door frames may sweat water. This is not a
malfunctioning of the unit.

2.5 Connections

Refer to the amperage data in this manual or on data plate and your local code or the National Electrical
Code to be sure unit is connected to the proper power source. Verify correct incoming voltage according
to the Data Plate information.
The data plate is located inside the unit, near the top front left corner. Under any circumstances
shouldn´t be removed from the unit.
The data plate is essential to identify the particular features of your unit and is of great benefit to
installers, operators and maintenance personnel. It is recommended that, in the event the data plate is
removed, you copy down the essential information in this manual for reference before installation.
A protected circuit of the correct voltage and amperage must be run for connection of the supply cord.
Unit must be grounded and connected in accordance with NEC Article 422 Appliances.

2.1 Tapping Instructions

This cooler will accept only the quarter-size keg. The Sankey type is the most modern and easiest of all
to tap with the available taps. The type of keg and tap you use will depend on the brand of beer your
purchase. Your beer distributor can provide additional instructions and tips on how to maintain the beer
to your satisfaction.
Following these tapping instructions, place the keg in front of cabinet for tapping. After all connections
are complete and checked for leaks, place the CO2 bottle in the rear (inside) of cabinet with the
pressure gage visible for reading, then place the keg in position, allowing the door to be closed
completely without interference. Make certain that beer line and keg are not touching the evaporator.
4