INSTALLATION
This product is only suitable for professional use. This device should be kept dry to avoid moisture,
overheating or dusty environment. Ensure that the unit does not come into contact with water or any
other liquid.
MBAR 4 72 BAT can be placed in a stable surface or stand but the common operating mode is rigging
it in a truss system. Please, check and follow the next recommendations for safe use of this device:
-
The truss system must be built in a way that it can hold 10 times the weight of all rigging
elements for 1 hour without any harming deformation.
-
The fixation system (clamps or hangs) must be able to hold 10 times the weight of the device.
-
The device must always be secured with a safety attachment, e.g. steel cable.
-
The operator must check that the installation meets the safety standards and the device
installation is approved by a skilled person.
DMX Connection.
The DMX cable must use the professional shielded twisted pair cable. Standard loudspeaker cable is
not reliable to control the long-range data. 24AWG cable is suitable for up to 300 meters long-distance
signal transmission; for longer distances, a DMX 512 signal amplifier should be used.
Don't overload the connection. One continuous connection can only support up to 30 devices. It is
advisable to use a DMX splitter in order to distribute the signal without losing its integrity.
Connect the DMX512 input terminal to the controller. After that, connect the output terminal to the
next device. Repeat this step with all fixtures in the chain. To prevent system errors, the last device in
a DMX chain needs to be equipped with a terminating resistor (120 ohm, 1/4 Watt).
Pin occupation
Pin 1: Ground
Pin 2: Pin -
Pin 3: Pin +
3