PEAK HOLD MODE OPERATION
START
(System initial)
*Note 1
Setting Target Torque
Apply Torque
Released
Apply Torque
Current Torque Value
(Peak Hold)
Reach 80% of Target Torque
...))...)) ((...((...
((...((...
Buzzer
Reach Target Torque
((((((((
))))))))
Buzzer
Note:
1. If
is displayed, that means this wrench has ever been
applied more than 110% of torque of the spec.
2. If
is displayed, that means the wrench's memory is
full and the next value record can not be written in. Please refer
the "Peak Hold Mode Recorded Value Review" section to clear
the momory records.
3. When 80% of the target torque is reached, the green LED will
begin to flash and the alarm tone will beep intermittently.
4. When the target torque is approached, the alarm will change to a
steady tone and the green LED will stop flashing and stay on.
The red LED will also illuminate.
*Note 2
Recording
Flashing
*Note 3
...)) ...))
Green LED
Reach 80% of Target Torque
*Note 4
(((((((
)))))))
Red LED
Approached Target Torque
9