ALLURE ® QS3 SERmES
RANGE
HOOD
Page 5
CONNECT WIRING
INSTALL HOOD
WARNING: To reduce the risk of electric
shock,
make sure power is switched
off at the service
panel. Lock or tag service panel to prevent power
from being switched
on accidentally.
iiii!
HOUSE
WIRING
(120 VAC)
CARDBOARD
protect
cooktop)
Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard
to protect the cooktop, if necessary.
GREEN
GROUND
SCREW
F_
Connect house black to hood black wire, house white to hood
white wire, and house ground under Green Ground Screw=
Securely tighten cable clamp onto house wiring=
rq
ra
KEYHOLE (4)
MOUNTING SCREW(4)
Hang hood from (4) Mounting
Screws.
Slide hood towards
wall until mounting screws are engaged in narrow end of (4)
Keyholes.
Tighten
mounting
screws
securely.
A long
screwdriver works best.
Replace bottom cover.
DUCT
TAPE
Connect ductwork to hood. Use Duct
to make
Tap__
joints
secure and air tight.
PAR20
50W MAX.
HALOGEN
BULB (2)
-or-
R16,
40W MAX.
iNCANDESCENT
BULB (2)
Fq
install (2) PAR20, 50 W Maximum Halogen BuBbs or (2) R16,
40 W Maximum
Incandescent
Bulbs.
Purchase
bulbs
separately.
CAUTION:
Bulbs may be hot! Refer to bulb packaging
for further
information.
F_
Replace filters, turn on
at sen,be panel, and test for
power
proper operation.