Descargar Imprimir esta página

CORREX UP 2.3-919 Instrucciones De Uso página 35

Sistema de corriente impresa para calentadores-acumuladores de agua esmaltados

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

8. Use only the original sealing material.
N N o o t t e e : : If the CORREX
existing holes of former insulated-hole mounted magnesium anodes can be
used.
7 7 . . 2 2 . . 2 2 S S k k e e t t c c h h : : F F i i t t t t i i n n g g a a n n d d c c o o m m m m i i s s s s i i o o n n i i n n g g
The illustration on the fold-out page (chapter 11.1) of this manual shows an
example of the installation procedure for a CORREX
tion shows the installation in a flange-type cover. The actual situation depends
on tank type, tank size, type of anode and connecting cables used.
N N o o t t e e : : Leave the fold-out page (chapter 11.1) open when installing the system.
The following parts are need for fitting:
1. Titanium anode (1 1 )
2. Connecting cables (3 3 )
3. Plug-in potentiostat (2 2 )
4. 1 seal (Viton) (4 4 )
5. 1 Insulation sleeve M8x2 (5 5 )
6. 1 Diode board
7. 2 Hex nuts M8 (7 7 ) and (9 9 )
8. 1 Tooth lock washer with tab connector 6.3 x 0.8 mm (8 8 )
7 7 . . 2 2 . . 2 2 . . 1 1 R R e e t t r r o o f f i i t t t t i i n n g g k k i i t t f f o o r r i i n n s s u u l l a a t t e e d d - - h h o o l l e e m m o o u u n n t t i i n n g g
I I n n s s t t r r u u c c t t i i o o n n s s f f o o r r t t h h e e i i n n s s t t a a l l l l a a t t i i o o n n o o f f t t h h e e t t i i t t a a n n i i u u m m a a n n o o d d e e
1. Scope of application
The retrofitting kit permits installing the titanium anode and the required
components in conformity with the requirements for insulated-hole mounting.
2. Illustration
Fig. 4 in the Annex 'Mounting kit for retrofitting' shows the order in which
the individual parts are to be installed.
N N o o t t e e : : Use the illustration as a visual aid for the installation.
3. Installation
The installation is effected in compliance with chapter 7.2.3
7 7 . . 2 2 . . 3 3 I I n n s s t t a a l l l l a a t t i i o o n n o o f f t t h h e e C C O O R R R R E E X X
1. Empty the storage tank, if necessary.
2. For retrofitting, remove the old protective (Mg) anode, if any.
3. If not yet existing, drill a hole with a diameter of 10.5 mm into the
flange-type cover of the hot-water strorage tank.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s CORREX
®
UP system is installed by way of retrofitting, any
® ®
U U P P s s y y s s t t e e m m f f o o r r i i n n s s u u l l a a t t e e d d - - h h o o l l e e m m o o u u n n t t i i n n g g
®
UP 2.3-919
®
UP system. The illustra-
35