Jandy
4.
Slide new lid on top of Light Controller, ensure the new lid is
pushed down firmly.
5.
Secure new lid to the Light Controller using the screw.
6.
Turn the power on at the breaker panel.
Transformer Replacement
To reduce the risk of electric shock, fire or injury, service should only be attempted
by a qualified pool service professional.
Risk of electric shock which can result in serious injury or death: Before attempting
to install or service, ensure that all power to the circuit supplying power to the
system is disconnected or turned off at the circuit breaker. All wiring must be done
in accordance with the National Electrical Code® (NEC)®, NFPA-70®, including
those in Article 680 - Swimming Pools, Fountains, and Similar Installations.
In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be followed. All
applicable local installation codes and regulations must be followed.
LED Light Controller is in acceptable working condition; including all seals/gaskets
must be in place and functional; grounding lug must be present, functional, and
bonded; and corrosion must not compromise ingress protection against weather.
Additionally, all hardware must be present and functional. If any of the
aforementioned conditions are not met, a new enclosure MUST be used.
1. Turn off power to the Light Controller at the breaker panel.
2.
Remove Light Controller lid screw.
3.
Pull lid up and remove from Light Controller.
4.
Unplug white transformer input wire connector harness,
see Figure 2.
5.
Use 14mm wrench to remove transformer nut, see Figure 2.
6.
Remove transformer washers and gasket, see Figure 2
Page 6
Infinite WaterColors
®
LED Light Controller | Spare Parts Installation Manual
™
WARNING