■ High or low extreme temperatures that a battery can be subjected to during use, storage
or transportation:
– during use: -10°C to 40°C / 14°F to 104°F
– storage: -10°C to 40°C / 14°F to 104°F
– transportation: -10°C to 40°C / 14°F to 104°F
■ Do not charge the battery longer than specified as this can reduce the battery's lifespan.
Charge the battery fully when using the unit for the first time.
■ Charge the battery at least once a month, even if you are not using it, to protect the
battery and ensure its longevity.
■ In the event of a leak, immediately contact the wholesaler, retail outlet or service centre
for assistance. If the battery acid has leaked, avoid any contact with the skin, eyes, and
mucous membranes. Should you accidentally come into contact with the battery acid,
rinse the affected area and contact a doctor.
■ To prevent the battery from overheating:
– When the room temperature ambient temperature reaches 65°C, the protection
will be activated. All device functions will turn off (light, fan, charging circuit).
– When the ambient temperature drops to about 60°C, the functions will not be restored
immediately. The user needs to perform operations to restore the device's function.
– When the function is available, all battery indicator lights will turn on until the user
resets the device.
– To initiate the reset the user will have to slide the switch to "O" level. If it is already
on "O" level, then it needs to slide to another level and return to "O" so that the PCB
can receive the signal.
READ AND SAVE THESE INSTRUCTIONS
4 | EN | Airhood (AH-01BE)
DESCRIPTION OF PARTS
Front view
1
2
3
4
1. Power switch
O – Off
I
– Low
II – Medium
III – High
2. Air duct tab
3. Air duct with front filter
Rear view
4. Main body
5. Air diffuser with tab
6. Handle
7. Battery indicator lights
8. Charging socket
9. Charger cord and plug
10. Rear filter (charcoal filter)
Airhood (AH-01BE) | EN | 5
5
6
7
8
9
10