Installation
Instructions
230/208 VOLT ELECTRICAL SUPPLY
HOW TO CONNECT
1
Remove
the
room
cabinet.
2
Connect
to electrical
power.
3 See
the
special
instHmtions
below
fl)r applicable
suI)ply
voltages.
4
Reinstall
the
room
cabinet.
Power
cords
may
include
an arc
fault
interruption
or
a leakage
current
detection
interruption
device.
A
test
mad reset
button
is provided
on the
plug
case
or
the
inline
case.
The
device
should
be tested
on a
periodic
basis
by first
pressing
the
TEST
button
and
then
the
RESET
button.
If the
TEST
button
does
not
trip
or if the
RESET
button
will not
stay
engaged,
discontinue
use
of the
Zonelhae
and
contact
a
qualified
service
technician.
A power
supply
kit must
be used
to suI)ply
power
to the
Zoneline
unit.
The
apl)ropfiate
kit is dete_nined
by the
voltage,
the
means
of electrical
connection
and
the
amperage
of the
branch
circuit.
Power supply kit
Connections
of 208
or 230 volt circuits
may be with
a
power
sui)pl ) kit or a junction
box
kit.
All wiring,
including
installation
of the receptacle,
must
be in accordance
with the NEC and local
codes,
ordinances
and
regulations.
I,ocal
codes
may require
the use of an arc tault
or leakage
current
detection
device
on the power
cord.
Be sure
to select
the
correct
cord
tot wmr installation.
© © @
Tandem
Perpendicular
Large Tandem
15Amp.
20 Amp.
30Amp.
230/208volt receptacle configuration.
Branch Circuit and
Proper GE Power Cord
Unit Amperage Bating
with LCDI Device
15
]_1(3153
20
1_I(3203
30
],L&K3303'::
':Not at)t)roved
{i)r use on 7000 BTU models.
I
Order
l¢dt RAK4002A
for
230/208
_olt
direct
connecti(}n.
IF USING AN ELECTRICAL
SUBBASE
230/208
xolt
models
ma)
be installed
using
one
of
the fi}llowing
electrical
subbases:
Branch Circuit and
Proper GE
UnitAmperage Bating
Subbase Kit
15
]L_K204D15P
20
]L_K204D20P
30
],L_F,204D30P*
*Not al}l}ro_vd {or use on 7000 BTU models.
Electrical
subbases
provide
an enclosure
lot direct
connection
or enclosed
receptacles.
The subbase
kit
includes
the power
cord.
The instructions
provided
with the selected
subbase
kit
must be careflfllv tollowed.
It is the responsibiliD'
of the
installer
to ensure
the connection
of components
is
done
in accordance
with these instructions
and all
electrical
codes.
I