RESET TO FACTORY STATE
ATTENTION
There is one Reset button on the back of rear panel.you can press this button for 3 seconds
with sound tip,"please input initialization passcode,"enter:
Then the lock is under factory state, the default master password is: 123456
you can open the door with any fingerprint or default master password.
Pull
1
DEAD LOCK FUNCTION
5
ATTENTION
There is one privacy button on the back panel.
You can pull downward this button with sound tip "Secure Lock is on", then the lock is
dead locked inside, only the administrator can access the door, other user password or
card will be invalid. And you can pull upward the button one more time with sound tip
"Secure lock is off" to cancel this function. Notice even it is dead locked, you can still
press handle inside to unlock the door without limit.
Privacy Button
EN - 3 support@tmezon.com
000#
, with sound: "Successful".
Reset Button
2
3
PASSAGE MODE &BELL FUNCTION
Enter the valid password or touch the IC card or press the finger to open the door.
After unlock the door, you can press the number "
function. The lock will be under always open state, you can press any valid password
to cancel the passage mode and lock the door.
Bell function: You can press the button"#"to ring the bell.
PREPARING TO INSTALL
6
6.1 Line Drawing
Draw a horizontal center line inside and outside the door at 1 meter from the ground.
Fold the hole template, make the handle center line align at the door horizontal center
line, then draw out the hole lines at front and side.
Drawing Center Line
mm
DOOR FRONT/BACK
DOOR SIDE
Template-60/70# LATCH
Installation Template
Plantilla de Instalación
설치 템플릿
ﻗﺎﻟب اﻟﺗﺛﺑﯾت
ARROW UP
Diameter:1"[25mm]hole
3
"[60MM]Backset
Depth:4"[100mm]
2
8
2" 50
2"[ 50mm]
Thick door
1
3
8
"[35mm]
Thick door
3
1
4
"[ 45mm]
Thick door
FOLDALONG DOOR FRAME
▶
2
3
"[70MM]Backset
4
1
inches
8
Drill Hole with Template
Step 1
EN - 4 support@tmezon.com
123#"
to activate the passage
i
Test with Mortise
Drill hole for Strike
Step 3
Step 2
i