Descargar Imprimir esta página

SOLAX Triple Power BMS Parallel Box-II G2 Manual De Instalación página 87

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
Communication Cable Connection / Kommunikationskabelverbindung / Connexion
du câble de communication / Conexión de cable de comunicación / Ligação do
cabo de comunicação / Aansluiting communicatiekabel / Collegamento del cavo di
comunicazione / Połączenie przewodu komunikacyjnego / Připojení komunikačního
kabelu / Anslutning av kommunikationskabel / Conexiune cablu de comunicare /
Свързване на комуникационния кабел / Kommunikationskabeltilslutning / Σύνδεση
καλωδίου επικοινωνίας / Sidekaabli-ühendus / Tiedonsiirtokaapelin liitäntä / Priključak
komunikacijskog kabela / Kommunikációs kábel bekötése / Duomenų ryšio kabeliai
/ Sakaru kabeļa savienojums / Pripojenie komunikačného kábla / Komunikacijska
kabelska povezava / İletişim Kablosu Bağlantısı / Conexão do Cabo de Comunicação
For T-BAT-SYS-HV-5.8 (RS485 I, BMS):
1
There is a protection cover for the RS485 connector. Unscrew the cover and plug one end of the RS485 I
communication cable to the RS485 I connector. Tighten the plastic screw nut which is set on the cable with a
rotation wrench. The operation is the same as above if connecting to the COM1/BMS connecter.
HV11550 "RS485 I" to Parallel box Slave "485";
HV10230 "COM1" to Parallel box Slave "S-CAN";
T-BAT H 5.8 / MC0600 "BMS" to Parallel box Main "M-CAN".
Slave
Main
Connect the communication cable from the parallel box to the COMM/BMS/RS485 I communication port that
2
is on the left side of the battery module.
* When the BMS Parallel box- Ⅱ G2 is connected to T-BAT-SYS-HV-5.8 battery modules,
if the BMS port of T-BAT H5.8 is erroneously connected to the S-CAN port of BMS Parallel
box- Ⅱ G2, it can still operate and function normally. However, in this configuration, the
master group cannot be upgraded properly.
• The wire order of the communication cable is as follows:
Sequence
1
SLAVE
VCC_485 GND_485
RS485 I
SLAVE
VCC_1
S-CAN
MAIN
/
M-CAN
84
For T-BAT-SYS-HV-3.0 (COM1, BMS):
2
3
B2
GND
VCC_2
GND
/
B
+
B
-
4
5
N-
P+
CANH
CANL
BMS_H
BMS_L
6
7
A2
VCC_485_2 GND_485
GND
N-
/
A1
8
P+
B1

Publicidad