3.8 Instructions for use
Accessories and how they are used
Accessories
PE VC 20 synthetic dust bag (203854)
PE VC 40 synthetic dust bag (203852)
VC 20 paper dust bag (203858)
VC 40 paper dust bag (203856)
VC 20/40 dry filter (2121386)
VC 20/40 universal filter (2121387)
VC 20/40 performance filter (2121388)
Suction hose, 27 x 3.5 m AS
Suction hose, 36 mm
Suction hose, 36 x 5 m AS
VC 20-UM
VC 20-UME
VC 40-UM
VC 40-UME
▶ A plastic dust bag or paper dust bag must always be used. This is essential.

4 Technical data

4.1 Rated voltage

Note
When powered by a generator or transformer, the generator or transformer's power output must be at
least twice the rated input power shown on the rating plate of the appliance. The operating voltage of
the transformer or generator must always be within +5% and -15% of the rated voltage of the appliance.
Rated voltage
Rated power input
Maximum load on built-
in power outlet for elec-
tric tools (if fitted)
Mains connection (type)
Rated voltage
Rated power input
Maximum load on built-
in power outlet for elec-
tric tools (if fitted)
Mains connection (type)

4.2 Maximum volumetric flow rate and maximum vacuum

Maximum
950 W
volumetric
1100 W
flow rate
1200 W
(air)
24
Printed: 15.02.2016 | Doc-Nr: PUB / 5267661 / 000 / 00
100 V
110 V
1200 W
1200 W
1600 W
VCTF
A07 QQ­F
3 x 2.0 mm²
3 / 12 AWG
220 - 240 V
220 - 240 V (CH)
1200 W
1200 W
2400 W
1100 W
H07 RN­F 3G 1.5
H07 RN­F 3G 1.5
mm²
mm²
VC 20­U
VC 40­U
55 ℓ/s
55 ℓ/s
61 ℓ/s
61 ℓ/s
61 ℓ/s
61 ℓ/s
Type of use
Working with mineral materials, wet and dry
Working with mineral materials, wet and dry
Working with wood
Working with wood
Dry
Universal use, wet and dry
Heavy use, wet and dry
Wet and dry
Mainly wet, not for dust
Wet and dry
110 V
1100 W
H07 BQ­F
3G 1.5 mm²
220 - 240 V (GB)
1200 W
1800 W
H07 RN­F 3G 1.5
mm²
VC 20-UL
•/•
•/•
•/•
200 V
950 W
VCTF
3 x 2.0 mm²
240 V (NZ)
1200 W
1200 W
H07 RN­F 3G 1.5
mm²
VC 40-UL
•/•
•/•
•/•