Advertencia de ANSI de Estados Unidos
Equipment approved for ANSI/UL121201 and CSA C22.2 No. 213, Nonincendive
Electrical Equipment for use in Class I, Division 2, Group A, B, C, and D.
Ambient temperature: -29°C
EXPLOSION HARZARD WARNINGS:
External connections/hubs through the connectors as mentioned (HDMI
port, combo audio port, USB 3.1 Gen 2 port, DC-in jack, docking port, and
tri antenna passthrough connector) are NOT to be used in a hazardous
location. When used with a docking station (such as the office dock,
keyboard dock, or vehicle dock), the docking/undocking of the equipment
must be conducted outside the hazardous area. Docking/undocking in a
hazardous area is prohibited.
The tablet is to be only powered from the battery pack while in hazardous
locations. Power adapter is NOT certified to use in hazardous locations and
NOT to be used in hazardous locations.
The battery must only be changed in an area known to be non-hazardous.
DO NOT disconnect equipment unless power has been switched off or the
area is known to be non-hazardous.
DO NOT remove or replace a user-removable item (such as the battery
pack, micro-SIM card, smart card, etc.) while the circuit is live unless the
area is free of ignitable concentrations.
Replace the battery with battery model BP3S2P2100S-01 or BP3S3P3450P-
03, manufactured by Getac Technology Corporation only. Use of another
battery may present a risk of fire or explosion.
to
40°C
86