MODE 1 ("BASIC")
Preparation
1. Install one of the insulated track sections at the
entrance to each station.
2. Use the blue/red track power cable to connect the
connectors marked "bl" (blue) and "rt" (red) on
terminal "A" of the circuit board to the tracks.
3. Use the blue/red connecting cable to connect the
connectors „bl" (blue) and „rt" (red) on terminal
"Power" of the circuit board to the DC output of an
LGB throttle or power pack.
4. Plug the power supply cord into a house current
outlet.
Operation
Place a train on the track between the stations. Adjust
the throttle to a medium setting. After a short pause,
the train will start and proceed to one station. At the
station, it will pass over one of the insulated track
sections and stop. After the pre-set waiting time, it
will slowly accelerate in the opposite direction and
proceed to the other station. The train will shuttle
between the stations until the power is switched off.
MODE 2 ("WITH PROTOTYPICAL BRAKING")
Preparation
Hint: To set up this mode, you need two single-strand
wires (for example, LGB 50220) to connect the insula-
ted track sections.
1. Loosen the screws on the tracks and remove the
diodes. Install one of the insulated track sections
at the entrance to each station. The interrupted
rails of the two insulated track sections must be on
opposite sides of the track. The track between the
stations must be longer than the train.
2. Connect terminals "sw" (black) and "ws" (white)
on the circuit board to the insulated track section.
Loosen the screws on the insulated track sections
and trap the wire between the screw and the rail.
3. Use the blue/red track power cable to connect the
connectors "bl" (blue) and "rt" (red) of the termi-
nals, respectively, to the tracks.
4. Use the blue/red connecting cable to connect the
connectors "bl" (blue) and "rt" (red) on terminal
"Power" of the circuit board to the DC output of an
LGB throttle or power pack.
5. Plug the power supply cord into a house current
outlet.