MANUAL DE INSTALACIÓN Y MANTENIMIENTO
SERIE BETTER 33
1. WARNINGS
- Read and follow all instructions.
- Risk of electric shock, the pump must be connected to a grounded receptacle.
- To reduce the risk of electric shock, do not allow children to use this product.
- The electrical connection cannot be buried in the ground, it is necessary to lay the cord to prevent
damage from mowing or other machinery.
- To reduce the risk of electric shock, once the damaged cable is found and must be replaced immediately.
- To reduce the risk of electric shock, no extension of the cable is allowed.
- Do not pump flammable and explosive liquid.
2. CONDITIONS OF USE
The pump can operate continuously
BETTER 33
under the following conditions:
- Liquid temperature below +50.
- Non-corrosive liquid with less sand and sludge;
- The maximum size of solid impurities is 10mm.
- The immersion depth is not more than 5m.
This pump is completely sealed waterproof.
IP68 protection. With thermal protector. Used for fish pool, waterfall fish pool, waterfall, filtering, drai-
ning, agriculture, etc.
Liquid: clean water, sea water.
Note: The voltage and frequency of the power supply, (see the nameplate of the pump). nameplate of
the pump).
3. INSTALLATION
Attention: when this product works, it is forbidden in the water to wash, graze, swim, children are forbid-
den in the vicinity of water to play and so on.
Automatic float working principle: when the water level rises to the set height, the automatic float swit-
ches on and runs, the pump starts working; when the water level drops and is lower than the set height,
the automatic float cuts off the power and the pump stops working.
4. ELECTRICAL CONNECTIONS
1. Make sure that the voltage, frequency and phase are in accordance with those marked on the nameplate.
2. The electric pump must be reliably grounded, and a highly sensitive earth leakage circuit breaker (IN
30mA) must be installed to avoid the risk of fatal electric shock in the pump.
8
www.proindecsa.com / proindecsa@proindecsa.com