Programming the relay timer controlled activation:
- Switch off the power to the interface and set the dips as shown in the drawing.
- Press and hold down buttons P1 and P2 and power up the interface.
- The interface will sound one long beep and the green L1 and red L2 leds will flash each second.
- Set DIP 3 to OFF.
- To program the activation time for each timer-controlled relay, procede as follows.
1. Move the dip corresponding to the channel CHA, CHB, CHC or CHD you wish to set to ON.
2. The interface will activate the corresponding relay and begin the timer count (max. 60 s), marked by the sounding of the buzzer and the flashing of the leds.
3. Move the corresponding dip back to OFF when the desired time has been counted.
4. The interface will deactivate the relay and the buzzer will sound one long beep.
The relay activation time has been programmed!
- To exit the procedure press and hold down P1 and P2 for more than five seconds.
Programming additional functions:
Attention! Dips 3 and dip 4 must be set to OFF as shown in the drawing.
- Switch off the power to the interface and set dips 1 and 2 as shown in the table.
- Press and hold down buttons P1 and P2.
- Power up the interface.
- The interface will sound two long beeps.
The parameters have been set.
Multi-channel activation
Chosing the multi-channel function will allow you to assign more than one channel function to the TAG/CARD or RFID you are memorising (see paragraph 3 -
Memorising user codes locally). When the TAG/CARD or RFID is read, multiple channels will now be activated contemporaneously.
23
ON
ON
Additional functions
OFF
ON
Dip #1
Buzzer ON
Buzzer OFF
Dip #2
Multi-channel OFF
Multi-channel ON
1 2 3
4
1 2 3
4