Light
Power
M
Setup
Unit
Inflator
TEST
TROUBLE SHOOTING
Error
1. "Clamps icon" on top left
blinks
2. "COOLING" icon in the bottom
and 10 minutes counting
show in the LCD
3. "OVERLOADCOOLING" icon
in the bottom and 10 minutes
counting show in the LCD
4. "COOLING icon " in the
bottom on
5. "READY" is not on after all
connecting well
6. "F1" on
7. "F2" on
8. "F3" on
9. "F4" on
OFF
2MINS
Reason
Clamps might be wrongly
plugged, short circuit or there is
no connection.
The unit has been tried five
times in 10 minutes so the
internal battery is hot.
1) The unit's power is not
enough.
2) The unit has been tried five
times in 10 minutes so the
internal battery is hot.
The unit's temperature is higher
than 55°C.
Connected battery is below 2V
or above 12.6V.
The temperature is lower than
—25˚C
The internal circuit is broken
The unit temperature is below
10°C or higher than 45°C.
Timeout for charging
67
2 Mins OFF:
The device will be turned off automatically
if it is not be used within 2 minutes.
Alternatively, press and hold the power
switch (8) for 3 seconds to turn off the unit.
Solution
Reverse the battery
connections.
Allow the unit to cool.
Bring the unit into a colder
enviroment.
1) Double check your engine size
if it is suitable for this unit.
2) Allow the unit to cool.
Bring the unit into a colder
enviroment.
Bring the unit into a colder
enviroment and wait until the
unit to recover to 40°C.
1. Make sure your car battery is
12V.
2. Charge your car battery.
3. Remove all the loads (eg:
heater, air conditioner, light
etc) and try again.
Bring the unit to a warm
environment
Send the unit to the professional
place for repair
The booster can only be
charged between 10°C and
45°C.
The battery possibly goes bad
and do not advise customer to
use again