The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120 V, 60 Hz, 250W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
To gain access to the electrical components,
first locate and remove the EIGHT SCREWS on
the underside of the side shelf and main grill
body. Set screws and pieces aside.
FUEL INPUT
RATING:
GROUNDED
2.2 LB/H
POWER CORD
(1.0 KG/H)
BURN POT
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
G : GREEN
S : SILVER
20
ELECTRICAL WIRE DIAGRAM
j
K
W
G
GROUND
W
P
W
W
W
L
W
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
120 V, 200W,
0.375" X 5.000" / 9.5 X 127 MM
Next locate and remove the TEN SCREWS
on the underside of the main grill body. Set
screws and pieces aside.
W
K
GRILL PROBE
CONNECTOR
W
FAST-BLOW FUSE
P
Y
P
Y
R
W
W
R R
AUGER MOTOR
& FEED SYSTEM
120 V, 60 Hz,
2 RPM MOTOR
k
GRILL
S
PROBE
CONTROL BOARD
Y
Y
Y
DRAFT FAN
120 V, 60 Hz,
1 PHASE