Descargar Imprimir esta página

GEIGER M56F152 Instrucciones Originales De Instalación Y Funcionamiento página 13

Con desconexión final electrónica para persianas venecianas interiores, exteriores e el sombreado de terraza

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
7. Information for the specialist electrician
H
Caution: Important installation instructions.
Please follow all instructions since
incorrect installation can lead to
the destruction of the motor and the
switching unit.
• A locking switch is here necessary (no simultaneous
UP and DOWN commands).
• The operations with the service clamps may be
accomplished only by an electrical specialist.
• Motors with electronic limit stops can be connected in
parallel.
• In this case the maximum load of the switching unit
must not be exceeded.
• When changing the running direction the switchover
must be effected through an off-position.
• When changing the running direction the switchover
time must be at least 0.2 s.
• With a three-phase network, please use the same
external conductor in order to control the UP and
DOWN directions.
• Connecting cables with plug connectors of the
Hirschmann Company are tested and approved with
couplings of the Hirschmann Company.
• In order to prevent a malfunction caused by coupling,
the supply line (ref. NYM) from the actuator/switch to
the motor must not exceed 100m in case of motors with
electronic end stops.
8. Setting of the end stops
General information
In order to set the end positions of the GJ56.. E14-1002 motors, any setting switch can be used
that has a programming key or that allows a simultaneous UP/DOWN command. In this case,
the UP/DOWN keys must be activated simultaneously instead of the programming key.
Article number / GEIGER setting switch
M56F152
M56F153
M56F154
I
Important: please observe the connecting diagram on the back of
the GEIGER setting switch.
Factory setting
• The motor is set on the middle position at the factory.
• The motor command is in normal operation.
I
If the factory setting has been carried out, max. 100/500 revolutions
can be done upwards or downwards.
Reset to factory settings for a further run downwards.
www.geiger.de
with service terminal (D), 5 wires, SMI compatible
with service terminal (CH), 5 wires, SMI compatible
with service terminal (D), 4 wires
Mains: 230V / 50Hz
L1
N
PE
PE
N
1
2
3
Electronic /
mechanical
limit stop
EN
5
EN

Publicidad

loading

Este manual también es adecuado para:

Gj56 e14-1002 serieM56f153M56f154