13. What to do if...
Problem
Motor does not run.
Instead of in the downwards direction,
motor runs upwards.
Motor only runs in one
direction.
After running several times,
the motor breaks down and
no longer responds.
14. Maintenance
The drive is maintenance-free.
15. Technical data
Technical data GJ56.. E14-1002 with electronic end stop
Voltage
Current
Cos Phi (cosj)
Inrush current (factor)
Power
Torque
Speed
Protection class
Limit switch range
Operating mode
Length
Diameter
Weight
Humidity
Storage temperature
Subject to technical modifications. Please find information to the ambient temperature range of our
GEIGER motors under www.geiger.de
16. Notes on waste disposal
Recycling of packaging materials
In the interest of environmental protection, please contact your local government's recycling or
solid waste management department to learn more about the services it provides.
Waste disposal of electric and electronic equipment
Electrical and electronic equipment must be collected and disposed of separately in accordance
with EU regulations.
www.geiger.de
Solution
• Motor not plugged in.
Please check the plug connection.
• Check connecting cable for possible
damage.
• Check the mains voltage and allow the
cause of the voltage break down to be
tested by a specialist electrician.
• The control leads are interchanged.
Exchange black/brown control leads.
• Motor in the end position.
Run motor in the opposite direction.
Readjust the end positions, if necessary.
• The motor became too hot and has
switched off.
Try it again after a cooling time of about
15 min.
GJ5603
230 V~/50 Hz
0,75 A
> 0,95
x 1,2
170 W
3 Nm
124 rpm
IP 54
1.000 rotations
S2 4 min.
356,7 mm
55 mm
ca. 2,20 kg
dry and non-condensing place
T = -15°C .. +70°C
GJ5620
0,85 A
190 W
2 x 10 Nm
26 rpm
200 rotations
361,7 mm
7
EN
EN