MODEL 8145NC – WIRING TO VARIOUS CONTROLS
Suggested Controls:
• Aprilaire IAQ Control Models 8910, 8910W or 8920W
• Aprilaire Thermostat Models 8620 or 8620W
• Aprilaire Model 8120X Digital Ventilation Controller
Select the diagram that corresponds to the control to be used . Wire the controls to the HVAC equipment and any other IAQ accessory in accordance
with the literature provided with the control .
FIGURE 6 – WIRING TO IAQ CONTROL
CONTROL MODULE OF IAQ CONTROL
SEE
NOTE 1
NOTE 1: An outdoor temperature sensor must be installed to use outdoor
temperature limits for ventilation control .
FIGURE 7 – WIRING TO THERMOSTAT
I2
VENT
FIGURE 8 – WIRING TO MODEL 8120X
W
Gs
Gh
MODEL 8620/8620W THERMOSTAT
C
I1
O/B
Y
Y2
G
RC R
W2
W
MODEL 8120X DIGITAL VENTILATION CONTROLLER
R
SEE NOTE 1
C
Y
O
VENT
L
S2
S1
T1
T2
SEE NOTE 1
ODT
VENT
English 5