For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.
Trouble
1. FAN WILL NOT START.
2. FAN SOUNDS NOISY.
3. FAN WOBBLES
EXCESSIVELY.
4. REMOTE CONTROL
DOES NOT WORK. THE
CONTROL INDICATOR
LED IS CONSTANTLY
FLASHING.
5. NOT ENOUGH AIR
MOVEMENT.
Troubleshooting
Probable Cause
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Dead battery in remote control.
4. Reverse switch in neutral position.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Screws securing fan blade holders to motor
flywheel are loose.
4. Wire connectors inside housing rattling.
5. Screws holding blades to blade holders are loose.
1. Setscrew in downrod support is loose.
2. Setscrew in downrod/hanger ball assembly is loose.
3. Screws securing fan blade holders to motor hub
are loose.
4. Blade holders not seated properly.
5. Hanger bracket and/or ceiling outlet box is not
securely fastened.
1. The battery/batteries are going to run out.
WARNING
1. Check main and branch circuit fuses or circuit
2. Check line wire connections to fan and switch wire
3. Replace with new battery.
4. Make sure reverse switch position is all the way to
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing are
3. Check to make sure the screws which attach the fan
4. Check to make sure wire connectors in switch
5. Tighten screws securely.
1. Tighten both setscrews securely in downrod support.
2. Tighten the setscrew in the downrod/hanger ball
3. Check to be sure screws which attach the fan blade
4. Check to be sure the fan blade holders seat firmly
5. Tighten the hanger bracket screws to the outlet box,
1. Please replace the battery/batteries.
1. If possible, consider using a longer downrod (not
17
Suggested Remedy
breakers.
connections in the switch housings.
CAUTION: Make sure main power is turned off !
one side.
snug (not over-tight).
blade holders to the motor flywheel are tight.
housing are not rattling against each other or
against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off !
assembly.
holders to the flywheel are tight.
and uniformly to the surface of the motor housing.
If holders are seated incorrectly, loosen the screws
and retighten.
and secure outlet box.
included, you can buy the longer downrod from
fanimation.com).