Insulated Flue
CONNECTION TO FLUE
Connect
the
equipment to the flue /
chimney checking that the
exhaust pipe doesn't take
up the free section of flue.
Employ
only
equipped with seal gasket.
Limit the use of horizontal
tubes ( max 2 meters ) and
curves.

CHIMNEY CAP

The chimney cap should have the following characteristics:
It's advisable to read, follow and respect what indicated in Normative and prescriptions.
Internal section equivalent with the chimney one.
Exhaust section exit not lower to the double of the chimney internal one.
Built in a way to avoid rain, snow or external body entrance, to ensure the right exit of
combustion products with any type of wind.
Positioned to guarantee the right fumes dispersion especially out of re-flux area. This area
has several dimensions and conformations in function of inclination corner of the covering
so it's necessary to apply the minimal highness as indicated in the following tables:
heating
tubes
37/120
IT-GB-FR-ES mod. 502-502X-502L-502LX