Setting the speed
Setting the torque cut-out
CS Unitec, Inc., 22 Harbor Ave., Norwalk, CT 06850 • Toll-free: 800-700-5919 • Ph: 203-853-9522
Fax: 203-853-9921 • Email: info@csunitec.com • Website: www.csunitec.com
MAB 825/845
In addition to the mechanical gearbox, the machine also has
full-wave control electronics with which the speed can be infinitely
varied.
First set the appropriate gear stage, then adapt the speed
using the electronic speed control (31).
Gear stage
Stage 1
Stage 2
Stage 3
Stage 4
NOTE
►
If possible, always select a setting with low gear stage and
high motor speed. The motor is thus set to high torque and
protected against overheating under heavy load.
In order to protect the tool, the maximum torque of the machine
can be set using the controller (32).
When the maximum set torque is reached, the machine switches
off. After the cut-out, the machine must be switched off and then
on again at the ON/OFF switch (21).
CAUTION
►
Do not use this function to switch off the machine when cut-
ting threads in pocket holes.
Speed range
40 - 110 rpm
65 - 175 rpm
140 - 370 rpm
220 - 600 rpm
Operation
53