TROUBLESHOOTING
Always disconnect tool from air supply before performing any service on tool.
Correcting a problem while the tool is pressurized may result in injury from
fastener discharge or tool operation.
Your pneumatic fastening tool has been designed for long life and trouble-free
operation. However, if operating problems arise, please use the troubleshooting
information below to determine how to remedy the problem.
FASTENER DRIVING PROBLEMS
FASTENERS DO NOT DRIVE
COMPLETELY AFTER AIR PRESSURE
FASTENERS DO NOT DRIVE
COMPLETELY WHEN DRIVING IN
FASTENERS DRIVE TOO DEEPLY.
PROBLEM
FASTENERS DO NOT
DRIVE COMPLETELY.
IS INCREASED.
QUICK SUCCESSION.
DANGER
CORRECTIVE ACTION
AT TOOL: Turn adjustment dial to increase
nail drive depth. Add 2 - 3 drops of air tool
oil to inlet.
AT COMPRESSOR: Increase air pressure. Do not
exceed 120 psi/8 bar
Driver blade worn or broken.
See dealer for replacement.
Inadequate air flow. Use larger diameter hose.
Use compressor with larger storage tank. Keep
hose lines short. Check air hose for kinks or
other restrictions.
AT TOOL: Adjust lower safety element tip down
to decrease nail drive depth.
AT COMPRESSOR: Reduce air pressure.
(Do not reduce below 70 psi/4.8 bar.)