FASTENER DRIVING PROBLEMS
PROBLEM
TOOL OPERATES, BUT NO
FASTENER IS DRIVEN.
TOOL WON'T OPERATE
STAPLE JAMMED IN TOOL
NOSE, PREVENTING TOOL
TOOL CHECKS
Keep your nailer in top working condition by checking it daily. See your Grip-Rite
for service if part or operating problems are found. Never use a malfunctioning tool -
it could result in serious injury.
Workpiece Contact & Trigger
Check workpiece contact for proper operation before each use. Workpiece contact
must move freely and return to extended position when lifted from workpiece.
Trigger must operate freely.
Daily Inspection
• Check for broken, damaged, or excessively worn parts, and repair or
replace as needed.
• Check for air leaks at trigger, cap, and nose. Disconnect tool from air supply
immediately if leaks are present, and see dealer for service.
• Make sure all screws are tightened securely.
FROM OPERATING.
TOOL LEAKS AIR.
TROUBLESHOOTING
CORRECTIVE ACTION
Check nose for jammed fastener. Clear jam
and reload magazine. Check staple strips for
smooth feeding in magazine.
Remove jammed fastener.
Check magazine for incorrect, bent, or loose
fasteners, and discard.
Reload using Grip-Rite
Check for source of leak, and tighten fittings
and screws as required. Discontinue using tool
if air leaks at trigger area or from cap exhaust.