Danger – powerful magnetic fields
Powerful magnetic fields can adversely affect persons with active
medical implants (e.g. pacemaker) as well as electromechanical
devices (e.g. magnetic cards, mechanical clocks, precision
mechanics, hard disks).
With regard to the effect of powerful magnetic fields on persons,
the applicable national stipulations and regulations must be
complied with such as BGV B11 §14 „electromagnetic fields"
(occupational health and safety - electromagnetic fields) in the
Federal Republic of Germany.
To avoid interference/disruption, always keep the implant or device
a safe distance of at least 30 cm away from the magnet.
Technical data
Electronic measuring precision
Display accuracy
Vial
Laser class
Laser wavelength
Operating conditions
Storage conditions
Auto power off
Power supply
Dimensions (W x H x D) G40
Dimensions (W x H x D) G80
Weight G40 / G80
EU and UK directives and disposal
This device complies with all necessary standards for the free
movement of goods within the EU and the UK.
This product, including accessories and packaging, is an electrical
appliance that must be recycled in an environmentally appropriate
manner in accordance with European and UK directives on waste
electrical and electronic equipment, batteries and packaging, in
order to recover valuable raw materials.
Further safety and supplementary notices at:
https://www.laserliner.com
DigiLevel Laser G40/G80
(Subject to technical change without notice. 23W23)
± 0.1° at 0° ... 1°
± 0.1° at 89° ... 90°
± 0.2° at 1° ... 89°
1 decimal place
± 0.5 mm/m
2 / < 1 mW
515 nm
0°C ... 40°C, max. humidity
80% rH, no condensation,
max. working altitude
2000 m above sea level
-10°C ... 60°C,
max. humidity 85% rH
after 3 minutes
2 x 1.5V LR03 (AAA)
400 x 66 x 30 mm
800 x 66 x 30 mm
566 g / 966 g (incl. batteries)
13