Remove the depth control knob (see Figure 15, page 7).
Lift cap slightly and remove the side cover.
°
Disengage the spring from the latch so that the pulleys
will turn freely (see Figure 28).
Figure 28 - Right Side of Planer with Side Cover Removed
°
Remove fan belt by walking the belt (one groove at a time)
from both pulleys alternately. Pull the belt while turning
the pulleys at the same time. Repeat with drive belt.
°
Replace with new belts. Walk the belt onto the pulleys in
the reverse manner as when removing the belts.
°
Make sure the belt is evenly seated on all grooves on
both pulleys.
°
Replace right side cover and knob. Secure cap with set
screws. Replace sensor and secure in position. Secure
display cover in position. Replace handle and secure
with plug and socket head bolt.
CALIBRATING
THE THICKNESS
PRESET
GAUGE
Refer to Figure 29, page 14.
Loosen hex nut (Key No. 64). Carefully turn gauge stop (Key
No. 65) to desired position. Gauge stop has 16TPI thread,
one full turn of gauge stop will change the rollercase position
0.062" relative to the thickness preset gauge. Secure stop in
position by tightening hex nut.