MAINTENANCE OF THE VENTILATION SYSTEM
Follow these simple instructions to clean the ventilation system of the pump:
A) Implement paragraphs 1-5 relating to cleaning the rotor turbine.
В) Use a plastic wire packed with service details and insert it into the hole of the motor shaft (Fig. 20).
С) In the event of any difficulties make Mirabello efforts. If this fails, try to gently insert the steel wire of suitable diameter.
D) If this action has led to the failure, it is necessary to put the pump housing into the diluted acetic acid and then try to clean it
with a wire. To do so, it is necessary to release the cord pump and to remove the locking mechanisms.
VII. TROUBLESHOOTING
If installation has been carried out correctly and the electrical accessories are operating normally, it is unlikely that any
technical problems will arise. If they should, consult an installer specialised in electrical appliances or contact the aquarium
product dealer to make a careful check or to replace the aquarium.
EN
FAULTS
The lighting system are not
in operation
Limited or no water flow
VIII. CORRECT DISPOSAL OF THIS PRODUCT
2012/19/UE (EN50419)
(Applied in European Union and countries, where the separate waste collection system is in force).
Please dispose of this equipment (plastic, glass, etc.) separately from other waste according to local legislation. The glass cover
of the case and electrical appliances should be disposed of separately. According to the directive on the 'RAEE' , electrical and
electronic equipment should be recyclable as described in this pharagraph. Disconnect the unit from the electric network before
removing parts from the aquarium. Make sure it is empty.
This marking shown on the product or its literature, indicates that it must not be disposed with other household wastes at
the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal,
please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
CAUSES
The lighting system is not connected to
the mains power supply socket or the jacks
between the power supply and the LED
hood cable are not properly connected.
A temporary black out
The lighting system is not operating
correctly
The flow pump is not connected to the
electrical socket
The filter cartridge is clogged
The pump is clogged due to dirt or wear
and tear on the rotor
The pump is not operating correctly
20
SOLUTIONS
Connect the plug to the electrical socket
---
Contact your local dealer
Connect the plug to the electrical socket
Rinse or replace the filter cartridge
Carry out maintenance on the pump.
Contact your local dealer
(WASTE ELECTRICAL & ELECTRONIC EQUIPMENT)