Service
Störung
Wasser fließt nicht
Filterset undicht
GB
Application
RO filter set
Reverse osmosis system for obtaining pure water.
The filter removes almost all dissolved minerals, salts and
other unwanted substances; salt retention rate 97%.
RO filter set with mineralisation
Water treatment system
Reverse osmosis system for obtaining pure water.
The filter removes almost all dissolved minerals, salts and
other unwanted substances; salt retention rate 97%.
The addition of magnesium (40 mg/l)* and silicate (SiO
(55 mg/l)* improves both the aroma and the taste of drinking water.
*) Average mineralisation at a capacity of 2,500 l.
Explanation of terms
RO
• Reverse osmosis
RO with mineralisation
• Reverse osmosis with mineralisation filter
Permeate
• Largely desalinated, purified 'water obtained by reverse
osmosis'.
Concentrate
• Wastewater that contains all the impurities removed from
untreated water.
Membrane
• Reverse osmosis membrane that desalinates and purifies
untreated water under high pressure and flow.
Water conversion factor (WCF)
• The water conversion factor (WCF) is the ratio between the
amount of pure water obtained (permeate) and the amount
of feed water required (raw water, e.g. soft water).
Safety information
• Installation and use of the system are subject to applicable
national provisions.
Ursache
• Keine Rohwasserzufuhr, da
Absperrventile im Zulauf geschlossen
sind
• Defektes Stromkabel
• Pumpe startet nicht oder ist hörbar
lauter
• Wasseraustritt innerhalb des Filtersets
oder Filterkartusche nicht dichtend
angeschraubt
• Use only genuine spare parts and accessories. The use
of other parts will result in voiding the warranty and the
CE marking, and could cause injury.
• The filter set is designed and constructed exclusively for the
intended use described here. Any other use is considered
'unintended use'.
• No liability can be accepted for damage that occurs due to
non-observance of the operating instructions.
• Prevent danger resulting from damaged power supply
cables. In case of damage, the mains cable must be
replaced by the manufacturer, their customer service
department or an equally qualified person.
• The filter set must be connected to a permanent power
supply.
)
2
• The filter set must be positioned upright.
• The filter set is exclusively suitable for use in closed
spaces.
• The filter unit must not be opened.
• At the installation location, the filter set must be protected
against mechanical damage, heat and direct sunlight. If
damaged, the filter set must not be put into operation;
otherwise the warranty will be void.
Do not install near heat sources, other ignition sources or
open fire.
• Installation of the tap and the filter set is only permitted in
frost-free rooms.
• The filter set may only be operated with cold water of
foodstuff grade in accordance with regional regulations.
• If the tap water is subject to a high particle load, it is
recommended to install a suitable particle filter upstream of
the reverse osmosis system.
• After being put into service, the filter set must not be
disconnected from the power.
• Do not use with microbiologically unsafe water.
• Filtered water is a foodstuff and must be used within 1 to 2
days.
• GROHE recommends disconnecting the filter set from the
water supply when the filter set is not used for an extended
period of time.
• GROHE recommends not leaving the filter set out of service
for extended periods of time.
13
Abhilfe
- Absperrventil prüfen und ggf. öffnen
und den Fließdruck überprüfen (RO
Arbeitsbereich ist: 1,0 bis 4,0 bar)
- Defekten Netzstecker austauschen
(achten Sie darauf, dass die grüne
LED permanent leuchtet)
- Informieren Sie den Kundendienst
- Pumpe defekt (Überhitzung)
- Pumpensicherungsdefekt
(Überhitzung)
- Informieren Sie den Kundendienst
- Geräte vom Strom- und Wassernetz
trennen
- Filterkartusche handfest anschrauben
(ein zu festes Nachdrehen mit zwei
Händen ist nicht notwendig)
- Informieren Sie den Kundendienst