Descargar Imprimir esta página

fadini Elpro 13 Folleto De Instrucciones página 6

Programador electrónico de microprocesador para automaciones en verjas de batiente de una sola o de doble hoja

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
GB
TERMINAL BOARD FOR
CONNECTING THE PULIN 3
BUTTON SWITCH
DIP-SWITCH
1
2 3
4 5 6 7 8
Elpro 13 exp FADINI
L1
L2
1
2
General description: The Elpro 13 exp is an electronic microprocessor programmer for controlling and managing single-phase gate openers fitted on swinging gates.
single-phase 230V±10% 50Hz power supply, it satisfies the Low Voltage 2006/95/CE and Electro Magnetic Compatibility regulations 2004/108/CE safety standards and
should therefore be installed by a qualified technician in compliance with applicable regulations. Programmed operation logic: automatic function, semi-automatic,
pre-flashing, step-by-step by radio remote control, input for 2nd pair of photocells, electric lock output, pedestrian opening function, stroke reversing pulse function,
operator status indicator light. The Manufacturer declines responsibility for improper use of the programmer and reserves the right to amend and update this man
ual and the programmer without prior notice. Not-compliance with installation rules can cause serious damage to properties and people.
IMPORTANT:
- The programmer must be installed in a protected, dry place with its own protective case
- Apply a high sensitivity differential Thermo magnet switch type 0.03 A to the programmer's power supply
- Make sure that the electronic programmer has a 230V 10% 50Hz power supply
- For power supply, flashing light use cable with wires with a section of 1.5 mm
2
wires with 1mm
sections.
- If the Photocells are not used, insert a jumper between terminals 1 and 2 and if the 2nd pair is not used, jumper the relativ e terminals
- If no Button switches or key switches without stop button are used, insert a jumper between terminals 3 and 6 NC contact
IF THE PROGRAMMER DOES NOT WORK:
- Ensure that the electronic programmer has a 230V 10% power supply
- Ensure that the electric motor has a 230V 10% power supply
- For distances of over 50 metres, increase the section of the wires.
- Check the single-phase 230V supply voltage
- Check the fuses
- Check all normally closed NC contacts of the programmer
- Check that there is no drop in voltage between the programmer and the electric motor
1643
Drwg. No.
6
13
exp
SUPPORT FOR
PLUG-IN RADIO CARD
CLOSING LEAF
DELAY TIME
-
0s - 18s
+
DWELL TIME
0s - 120s
-
+
OPERATING TIME
-
2s - 100s
ON
+
OFF
L3
L4
L5
L6
3
4
5
6
7
8
9
10
11 12 13 14 15
230V SINGLE-PHASE PROGRAMMER FOR SWING GATE OPERATORS
fuse 24v
F5= 1A
Opening Delay
Relay
Closing Delay
Relay
16 17
18
19 20
21
M1
M2
2
up to a distance of 50m; for Limitswitches and other accessories, use cables with
Diagnostic LEDs
L1= ON if the programmer is powered
L2= Photocell, normally ON, switches off with obstacle present
L3= Open, normally OFF, lights when Open pulse is received
L4= Close, normally OFF, lights when Close pulse is received
L5= Stop, normally ON, switches off when Stop impulse is given
L6= Radio, normally OFF, lights when Radio pulse is received
230V – 24V
Transformer
Transformer
fuse
F4= 630mA
Flashing light fuse
F3= 630mA
22 23
24
25

Publicidad

loading