OPERATING INSTRUCTIONS
en
52
O P E R A T I N G I N S T R U C T I O N S | WTM10L
Minimum distance in mm (y) between the set sensing
range and white background (90 % remission)
y
30
(1.18)
20
(0.79)
6%/6%
6%/90%
6%/6%
2
6%/90%
1
10
(0.39)
0
0
200
400
(7.87)
(15.75)
Recommended sensing range for
the best performance
Figure 10: Characteristic curve, WTM10L-xxxxx1
1
25
300
2
25
500
3
25
0
200
400
(7.87)
(15.75)
C/D
A
Recommended sensing range for
the best performance
Figure 11: WTM10L-xxxxx1
Black object, 6% remission factor, Mode 1: Speed
1
Black object, 6% remission factor, Mode 2: Standard
2
Black object, 6% remission factor, Mode 3: Precision
3
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Field of view
D
Adjustable switching threshold for background suppression
Blue
Recommended sensing range for the best performance
Table 8: WTM10L-xxxxx2, Short Range
WTM10L-xxxxx2, Short Range
Example:
Safe suppression of the background
6%/6%
6%/90%
3 3
Black object (6 % remission)
Set sensing range x = 500 mm
Needed minimum distance to white
x
background y = 10 mm
600
800
(23.62)
(31.50)
Distance in mm (inch)
700
600
800
(23.62)
(31.50)
Distance in mm (inch)
B
White background (90 %)
x
y
9382969/2024-02-23 | SICK
Subject to change without notice