Descargar Imprimir esta página

Truma AquaGo basic Instrucciones De Funcionamiento E Instalación página 9

Calentador de agua instantáneo de gas lp
Ocultar thumbs Ver también para AquaGo basic:

Publicidad

Idiomas disponibles

Idiomas disponibles

Removing the access door
1. Open the access door to Position .
2. Move the access door upwards to remove it.
I
Fig. 6
Closing the access door
Damage to the access door and the RV if
the access door is not closed properly!
• Make sure that the access door is flush
with the cover plate when closed.
1. If removed, insert the access door into the
cover plate.
2. Make sure that the webbing is not pinched
between the access door and the cover plate.
3. Press the access door against the cover plate.
4. Turn the turn lock clockwise
zontal position.
Fig. 7
II
into the hori-
close
Starting the appliance
Danger of over-temperature and toxic ex-
haust gases!
• Use with LP gas (propane) only. Butane or
any mixtures containing more than 10 %
butane must not be used.
• Keep the air inlet and exhaust gas outlet
free of obstructions. Do not lean any ob-
jects against the water heater's access
door or place any foreign objects within
2 feet (61 cm) of the access door.
Danger of combustion, personal injury
and damage to RV!
• Keep the area around the appliance free
from combustible materials, gasoline, and
other flammable vapors or liquids.
• Switch the gas supply and the appliance
off:
– if anything seems to be out of the ordinary.
– if you smell gas.
– if you move the RV.
– before entering a gas station.
– before entering a tunnel.
Inspections before each use
Check the appliance for the following points
before each use. In case of damage, contact an
authorized Truma service provider and do not
operate the appliance.
1. Check for visible damage, e.g., on the cover
plate or access door.
2. Provide adequate quantities of propane gas
and fresh water.
3. Switch ON and check 12 V power supply of
your RV.
4. Check that the access door of the appliance
is closed.
5. Keep the appliance free of foreign objects,
e.g., leaves, animals, spiderwebs, and keep
the area around free of snow and ice. The
appliance will not function properly if the
intake air or exhaust terminal is obstructed.
6. Do not cover vent pipe and fittings with ther-
mal insulation.