Descargar Imprimir esta página

Kenmore 79041013803 Instrucciones De Instalación página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Remove t he3 loose nuts(afteryouremove the
rubber band) ontheterminal b lockusinga3/8" nut
driverorsocket.
3.
Connect the neutral white wire of the copper power
supply cord to the center silver-colored terminal of
the terminal block, and connect the other wires to
the outer terminals. Match wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal).
4. Replace the 3 nuts on the terminal block. (See
Figure 3)
5. Lower the terminal cover and replace the 3 screws.
Silver colored
Terminal
wire
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
6. Replace the 3 nuts on the terminal block (see Figure
4).
7. Lower the terminal cover and replace the 3 screws.
Block
Colored
Terminal
Red
Wire
Terminal
Block
Black
wire
A strain relief
supplied
by the user
1-1/8"
Dia. Direct
must be installed
at
Connection
Hole. Punch
this location
To 240 V
out knockout
for
receptacle
1-3/8"
Dia. Cord Kit Hole
Figure 3
Four
Conductor
Wire
Connection
to
Range
(mobile
homes)
1. Remove the 3 screws at the lower end of the rear
wire cover, then raise the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection block (see figure 2).
2. Remove the 3 loose nuts (after you remove the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure 4).
Black
1-1/8"
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
A strainrelief
supplied by the user
must be installed at
To 240 V receptacle
this location
NOTE: Be sure to remove the supplied
_l
grounding
strap
Figure 4
Direct
Electrical
Connection
to the
Circuit
Breaker,
Fuse Box or Junction
Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief
at each end of the
cable. At the appliance end, the cable goes through the
Direct Connection
Hole (see Figure 4) on the Cord
Mounting
Plate. Wire sizes (copper
wire only) and
connections must conform to the rating of the appliance.
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutral
(white)
wire
(see Figure 5):
(The 3-conductor
cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box
connect the appliance and residence cable wires as
shown in Figure 5.

Publicidad

loading

Este manual también es adecuado para:

7904103980079041039804790410398017904104380179041043802