Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first device in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first device in the DMX-chain with the DMX-input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last device, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last device.
Connection with the mains
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
OPERATION
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Connect the connection cable-ends of the LED luminaries with the sockets of the controller.
Connect the controller to the mains with the power-plug.
With the POWER-switch, you can switch the device on and off.
You can select the programs by pressing the buttons on the controller.
Attention: The controller can be used with up to 12 luminaries.
International
L
N
DANGER OF FIRE!
18/40
Ω
resistor
51930450_V_1_0.DOC