Index Description
P48 Max. output in DHW
P49 Not implemented (b01=2)
P50 Not implemented (b01=2)
P51 Burner shutdown in DHW (P42=2)
P52 Burner ignition in DHW (P42=2)
P53 Solar standby time
P54 System pre-circulation time in heating
P55 System filling mode
P56 Minimum system pressure limit value
P57 System nominal pressure value
P58 Maximum system pressure limit value
Circulating pump deactivation with
P59
OpenTherm
P60 Frost protection power
P61 Minimum power
P62 Fan minimum speed
P63 Fan on speed
P64 Fan maximum speed
P65 Not implemented
P66 Valve frequency
P67 Installation C(10)3/C(11)3
P68 Flue parameter
P69 Heating hysteresis after ignition.
* Restore Factory Values
To restore all the parameters to the factory values, set parameter b29 to 10 and confirm. Turn the
power off for 10 seconds and then back on.
At this point it is necessary to restore parameter b02 and the modified parameters to the correct
value according to the type of boiler. Parameter b27 will be automatically set to 5.
EN
Range
0 - 100%
--
--
0 - 100
OFF = DHW user setpoint + P51
0 - 100
ON = DHW user setpoint - P52
0 - 255 seconds
0 - 255 seconds
0 = Disabled
1 = Automatic
0-8 bar/10 (Only for boilers with water pressure sensor)
5-20 bar/10 (Only for boilers with water pressure sensor)
25-35 bar/10 (Only for boilers with water pressure sensor)
0 = Circulating pump activated in heating
1 = Circulating pump deactivated in heating with request from Open-
Therm only
0 - 50% (0 = minimum)
0 - 50% (0 = minimum)
DO NOT MODIFY
(The parameters are automatically updated)
DO NOT MODIFY
(The parameters are automatically updated)
DO NOT MODIFY
(The parameters are automatically updated)
--
0 - 3
0 - 1 (1 = installation C(10)3 / C(11)3)
0 - 10 (modify according to flue table)
6 - 30 °C
cod. 3541V304 - Rev. 00 - 03/2024
Default
100
--
--
10
10
10
30
0
4
7
32
0
0
0
G20/G230:
24 kW = 47
28 kW = 47
34 kW = 49
G30/G31:
24 kW = 49
28 kW = 49
34 kW = 48
G20/G230:
24 kW = 160
28 kW = 160
34 kW = 140
G30/G31:
24 kW = 152
28 kW = 152
34 kW = 132
G20/G230:
24 kW = 140
28 kW = 172
34 kW = 194
G30/G31:
24 kW = 134
28 kW = 156
34 kW = 186
1
3
0
0
10
365