INSTALLATION INSTRUCTIONS ( CONTINUED )
Install Hose and Nozzle
1.
Wrap both threaded ends of the dispensing hose with 3 to 4 turns of thread
tape or a thread-sealing compound approved for use with petroleum fuels.
2.
Install one end of hose into the pump outlet port, using a wrench to tighten
securely. Install the other end into the nozzle and tighten securely using a
wrench.
24" - 40" Extension Pipe
Figure 2
Install Handle
Refer to illustrations Figure 3 and Figure 4 on page 8.
NOTE: This piston hand pump gives the operator a choice of two flow settings:
The 1/4-gallon setting has low resistance and pumps 1/4 gallon per stroke
cycle.
The 1/2-gallon setting has higher resistance and pumps 1/2 gallon per
stroke cycle.
The volume per stroke is determined by connecting the piston shaft to the
appropriate handle setting as outlined below.
NOTE: Clevis pins may be installed from either side of handle.
1.
Slide the handle grip onto the pump handle.
2.
To install the links on the pump, insert a long clevis pin through the link ends
and the pump's link holes. Secure with a small cotter pin (see Figure 3).
3.
Attach the free ends of the links to the bottom, outer surfaces of the handle.
Insert a long clevis pin through the holes on both links and the lowest hole
on the handle. Secure with a small cotter pin (see Figure 3).
4.
Insert a screwdriver in the piston shaft of the pump and pull the piston out.
Install the piston shaft to the handle at either piston hole on the handle by
placing a short clevis pin through the handle and the piston shaft end and
securing with the hitch clip pin.
5.
Select the upper piston hole on the handle for the 1/2-gallon setting (see
Figure 3) or the lower piston hole for the 1/4-gallon setting. Flow settings
can be changed at any time by repositioning the piston shaft on the handle.
6.
Lock the handle to the pump by pushing the handle against the pump and
inserting a padlock through either of the top holes in the handle and through
the pump's lock hole (see Figure 4).
EN
15" - 24" Telescoping Suction Pipe
7