Descargar Imprimir esta página

Qlima PGW312 Instrucciones De Uso página 41

Ocultar thumbs Ver también para PGW312:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
WARNING:
In the event of gas leakage, the appliance shall not be used
or if alight, the gas supply shall be shut off and the appliance shall be investi-
gated and rectified before it is used again.
3. Turn the gas supply ON. And check all the connections with the soapy
water solution. No bubbles may appear!
4. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then
turn the gas supply ON and recheck. Contact your dealer or gas supplier for
assistance if bubbles continue to appear.
DIAGRAMMATICAL REPRESENTATIONS OF OUTDOOR AREAS
Both ends open
ASSEMBLY:
Parts supplied: see pic 2
(note: AAA-battery, gas hose and regulator are not included – hose and regulator
must be purchased separately.)
Step 1:
Mounting the gas tube needs to be done when the burner base (6) is not yet
mounted to the pole (7). Connect your gas tube airtight to the gas inlet connector
(see pic. 3a + 3b). If needed:
make sure to use a tube clamp to tighten the tube securely and airtight.
For gas tubes with threaded connection: bind 2 or more rounds of plumbing
tape around the gas inlet connection before connecting the gas tube
The lid on the burner base (6) can be removed in order to have more access to
fixate the gas tube. (see pic. 3a)
Step 2:
Lead the lose end of the gas tube through post (7) see pic. 3c.
Step 3:
Use the provided bolts to connect (7) to (6) see pic. 4
Open
Open side must be >25%
of total wall area
>30% of Total wall area
to be open and unrestricted
4
41

Publicidad

loading