This laser level left the factory fully calibrated.
Kapro recommends that the user will check the accuracy of the
laser periodically, or if the unit falls or is mishandled.
1. Check the height accuracy of the cross created by the side
vertical and the horizontal beams.
2. Check the height accuracy of the cross created by the
front vertical and the horizontal beams.
3. Check the accuracy of the front vertical beam.
4. Check the accuracy of the side vertical beam.
5. Check the perpendicularity between the 2 vertical beams.
NOTE: All the calibration tests must be done in Automatic mode.
1. Checking the height accuracy of the cross created by
the side vertical and horizontal beams.
(Up and down deviation)
1) Place the laser on a table or on the floor between 3 walls
A, B and C. The distance between A and B should be
approximately 5 meters.
2) Place the laser approximately 0.5 meters from wall A
and 2 meters from wall C.
3) Turn the device ON and activate the bottom horizontal and
the 2 vertical beams.
4) Place the intersection point of the horizontal and the
side vertical beam on wall A. Place the intersection point of
the horizontal and the front vertical beams on wall C.
14
FIELD CALIBRATION TEST