BFT LEO-D-MA Instrucciones De Uso Y De Instalacion página 16

Ocultar thumbs Ver también para LEO-D-MA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
ENGLISH
These values allow the torque setting to be corrected.
If the istant torque value reached during the manoeuvres turns out to be consid-
erably close to the threshold value set in the parameter menu, future operation
failures are likely to occur due to wearing or small door deformations.
It is therefore advisable to check the maximum torque reached during some
of the manoeuvres carried out in the course of installation, and if necessary
set a value about 5-10 percent points higher in the parameter menu.
6.7) Autoset Menu (Autoset) Can be set with "Encoder"=2 only.
Allows you to automatically set the following parameters:
-
Torque
-
Brake
-
Slow-down space (50 cm)
WARNING!! Once the dist.sloud parameter has been edited, you will need
to run an autoset cycle.
WARNING!! The autoset operation is only to be carried out after checking the
exact leaf (opening/closing) movement, and correct limit-switch activation.
The autosetting operation is carried out from closing end-of-stroke devices.
During this phase, the control panel performs 3 manoeuvres at different levels
of opening/closing torque, slow-down torque, braking value.
Moreover, during autosetting, the leaf may be stopped, due to the checks
which are being carried out by the control panel.
After this, if autosetting is successfully completed, the control unit automatically
exits the (.... .... ....) phase, and displays the "OK" message which indicates
correct autoset execution.
If "KO" is displayed, this means that autoset was not correctly performed due
to the presence of resistance points which did not allow the correct setting
of the ideal operation values on the control unit.
Proceed to find out whether there are any mechanical obstructions which
might prevent regular leaf movement.
Furthermore, the autoset function will not be successful, due to the activation
of any of the inputs during the manoeuvre.
WARNING! During autoset, the installer must check the movement of the
automation and prevent persons or things from approaching or standing
within the automation operating range.
WARNING: Check that the impact force value measured at the
points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
6.8) Statistics
Having connected the universal palmtop programmer to the control unit, enter
the CONTROL UNIT / STATISTICS menu and scroll the screenful showing
the statistical parameters:
-
Board microprocessor software version.
-
Number of cycles carried out. If motors are replaced, count the number
of manoeuvres carried out up to that time.
-
Number of cycles carried out from the latest maintenance operation.
It is automatically set to zero after each self-diagnosis or parameter writing.
-
Date of latest maintenance operation. To be updated manually from the
appropriate menu "Update maintenance date".
-
Installation description. 16 characters can be entered for installation
identification.
7) INTEGRATED RECEIVER TECHNICAL SPECIFICATION
Receiver output channels:
-
output channel 1, if activated, controls a START command.
-
output channel 2, if activated, controls the excitation of the 2nd radio
channel relay for 1s.
Transmitter versions which can be used:
all Rolling Code transmitters compatible with
ANTENNA INSTALLATION
Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere with radio
reception. In case of insufficient transmitter range, move the antenna to a
more suitable position.
8) RECEIVER CONFIGURATION
Cloning operations can be carried out with the special (universal
palmtop programmer) programmer only. The on-board receiver combines
characteristics of utmost safety in copying variable code (rolling code) coding
with the convenience of carrying out transmitter "cloning" operations thanks
to an exclusive system.
16 -
LEO-D-MA - Ver. 06
INSTALLATION MANUAL
Cloning a transmitter means creating a transmitter which can be automatically
included within the list of the transmitters memorised in the receiver, either
as an addition or as a replacement of a particular transmitter.
Cloning by replacement is used to create a new transmitter which takes the
place of the one previously memorised in the receiver; in this way a specific
transmitter can be removed from the memory and will no longer be usable.
Therefore it will be possible to remotely program a large number of additional
transmitters or, for example, replacement transmitters for those which have
been lost, without making changes directly to the receiver.
When coding safety is not a decisive factor, the on-board receiver allows
you to carry out fixed-code additional cloning which, although abandoning
the variable code, provides a high number of coding combinations, there-
fore keeping it possible to "copy" any transmitter which has already been
programmed.
PROGRAMMING
Transmitter storage can be carried out in manual mode or by means of
the universal palmtop programmer which allows the complete installation
database to be managed through the Eedbase software.
In this second case, receiver programming takes place through the connec-
tion of universal palmtop programmer to the LEO-D-MA control panel, using
the UNIFLAT and UNIDA accessories as indicated in Fig. 4.
9) MANUAL PROGRAMMING
In the case of standard installations where advanced functions are not
required, you can proceed to manual storage of the transmitters, making
reference to fig. B for basic programming.
-
If you wish the transmitter to activate output 1 (START) by means of key1,
key2, key3 or key4, enter the transmitter in menu "Start key", as in fig. B.
-
If you wish the transmitter to activate output 2 (2nd radio channel relay)
by means of key1, key2, key3 or key4, enter the transmitter in menu "2nd
ch. key", as in fig. B.
Note: Hidden key P1 appears differently depending on the transmitter
model.
For transmitters with hidden key, press hidden key P1 (fig. B1). For transmit-
ters without hidden key, the key P1 function corresponds to simultaneously
pressing the 4 transmitter keys or, after opening the battery compartment,
bridging the two P1 points by means of a screwdriver (fig. B2).
IMPORTANT NOTE: ATTACH THE ADH ESIVE KEY LABEL TO THE
FIRST MEMORISED TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns the key
code to the receiver; this code is necessary in order to carry out subsequent
cloning of the radio transmitters.
10) RADIO-TRANSMITTER CLONING
Rolling-code cloning / Fixed-code cloning
Make reference to the universal palmtop programmer Instructions and the
CLONIX Programming Guide.
10.1) ADVANCED PROGRAMMING: COLLECTIVE RECEIVERS
Make reference to the universal palmtop programmer Instructions and the
CLONIX Programming Guide.
11) SERIAL CONNECTION USING SCS1 BOARD (Fig.5)
The LEO-D-MA control panel allows several automation units (SCS1) to be
connected in a centralised way by means of appropriate serial inputs and
outputs. This makes it possible to use one single command to open and
close all the automation units connected.
Following the diagram in Fig.5, proceed to connecting all the LEO-D-MA
control panels, exclusively using a telephone-type line.
Should a telephone cable with more than one pair be needed, it is indispens-
able to use wires from the same pair.
The length of the telephone cable between one appliance and the next must
not exceed 250 m.
At this point, each of the LEO-D-MA control panels must be appropriately
.
configured, by setting a MASTER unit first of all, which will have control over
all the others, to be necessarily set as SLAVE (see logic menu).
Also set the Zone number (see parameter menu) between 0 and 127.
The zone number allows you to create groups of automation units, each
one answering to the Zone Master unit. Each zone can only be assigned
one Master unit, the Master unit in zone 0 also controls the Slave units
in the other zones.
11.1) Opposite sliding leaves (Fig.6)
By means of a serial connection, it is also possible to obtain centralised
control of two opposite barriers/gates.
In this case, the Master M1 control panel will simultaneously manage closing
and opening for the Slave M2 control panel.

Publicidad

Tabla de contenido
loading