Installation
STEP 9 Connect the electrical wiring (for electric models)
Before connecting the electrical wiring, make sure you have read the "Electrical requirements" section on
page 31.
3-wire system
A
B
C
L2
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E.
/
" (1.9 cm) UL-listed strain relief
3
4
40
English
Untitled-1 40
1. Loosen or remove the screws from the center
terminal block.
2. Connect the neutral wire (white or center wire) of the
power cable to the center, silver-colored terminal
screw of the terminal block. Tighten the screws.
3. Connect the other wires to the outer terminal block
screws. Tighten the screws.
4. Tighten the strain relief screws.
D
5. Insert the terminal block cover into the rear panel of
the dryer. Then, secure the cover with a hold-down
screw.
L1
CAUTION
E
• To convert from the 4-wire system to 3-wire system,
connect the ground strap to the terminal block
support to ground the dryer frame to the neutral
conductor.
• Ring-type terminals are recommended. If using strap
terminals, make sure they are tightened.
• Connect the power cord and check L1/L2/D (N)
voltage. If the voltage is low, it may not heat properly.
Review the "Electrical requirements" section on page
31 if needed.
2023-11-09( )
11:53:38