Descargar Imprimir esta página

JB INDUSTRIES CLIMATE CLASS DV-22W Manual De Instrucciones página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

Zeroing Vacuum Gauge
1. Press and hold ENTER button to enter the menu
2. Press POWER button to cycle to "BARO_P" and press ENTER button
3. The screen will display "SET" indicating that the barometric pressure has been reset
Turning ON/OFF High Resolution
High Resolution mode enables the user to monitor the
vacuum level at smaller increments of pressure
1. Press and hold ENTER button to enter the menu
2. Press POWER button to cycle to "Display" and press
ENTER button
3. Press POWER button to cycle to either "Hi Res ON"
or "Hi Res OFF" and press ENTER button
Changing Sensor Head/Replacing Filter
1. Rotate the sensor locking dial to the unlock position
2. Grab the brass portion of the senor and pull it away
from the main body
3. To replace the filter, unscrew the brass sensor
component from the brass flare component
4. The filter will be located at the bottom of the threaded
portion of the flared brass component
5. Replace the filter and screw the two brass components
back together until the components are hand tight
6. To install a sensor, line up the indented line on the
brass body to the line on the sensor locking dial and
push into the body until the hex portion of brass
sensor is flush with the bottom of the sensor locking dial
7. Twist the sensor locking dial back to the locked position