3. Safety
3.6 Labelling, safety marks
Diaphragm seal
The diaphragm seal is marked with the material code and the mark of the person author-
ised for restamping.
EN
Product label
    
DE-63911 Klingenberg
Model + code of the hygienic certification
Without code = without hygienic certification
Code "H" = 3-A-compliant → See chapter 3.7
Code "E" = EHEDG-certified
IO-Link (if available)
P# product number
If the serial number becomes illegible (e.g. due to mechanical damage or overpainting),
traceability will no longer be possible.
Symbols
Before mounting and commissioning the instrument, ensure you read the
operating instructions!
Do not dispose of with household waste. Ensure a proper disposal in
accordance with national regulations.
3.7 Compliance with 3-A conformity
For a 3-A-compliant connection, seals in accordance with standards have to be used.
For compliance with conformity in accordance with 3-A standards, only the version with
circular connector M12 x 1, metal version, is permissible.
Compliance with conformity is only given for versions that are marked with the 3-A
logo in the data sheet. 3-A-compliant diaphragm seal systems are marked as model
DSSA11SA-H on the product label.
→ For further information, see data sheet DS 95.25.
3.8 Compliance with EHEDG conformity
For an EHEDG-compliant connection, seals in accordance with the current EHEDG
policy document must be used.
Seals for connections per DIN 32676 and BS 4825 part 3 are, e.g., manufactured by
Combifit International B.V.