MAINTENANCE
NOTE: This pump is designed for minimum maintenance. The motor
bearings are self-lubricating. Inspect the pump and components regularly
for fuel leaks and make sure the hose and power cord are in good condition.
Keep the pump exterior clean to help identify leaks.
IMPORTANT: Do not use this pump for water, chemicals or herbicides.
Dispensing any fluid other than those listed in the owner's manual (see
BEFORE YOU BEGIN: Fueling Requirements at front of manual) may
damage the pump. Use of the pump with unauthorized fluids will void the
warranty.
Clean or Replace Strainer
1.
Turn the pump off and disconnect from power. Using 5mm hex wrench,
remove the coverplate, O-ring, and inlet strainer and inspect for
damage or clogs (see Figure 1). Clean the strainer with a soft-bristled
brush and solvent. If the strainer is very dirty, compressed air may be
used. If damaged, replace the strainer.
2.
Clean the coverplate and O-ring. Coat the O-ring lightly with grease.
Reinstall the strainer, O-ring and coverplate. Ensure the O-ring is
properly seated and tighten securely.
Figure 1
EN
Coverplate O-ring
Strainer
Coverplate
7