6.3.3. Adjustment of product - manual block
(MH42 / MP42)
Adjust product for the manual block by using a limit-
ing nozzle located in the suction nipple of the non-
return valve (image 110009231).
•
Remove the unit cover.
•
Replace the nozzle with a smaller or larger one
to adjust concentration. Refer to the table for
guidance.
6.3.4. Changing air / foam on 1 or 2 products.
(MH42 / MP42)
All tests have been made with
Topaz LD1.
Nozzle colour
Clear
Pink
Light blue
Purple
Turquios
Yellow
Brown
Orange
Green
Tan
Blue
White
Red
Beige
Black
110009231
Grey
180°
1
→
Concentration by 20 Bar
/290PSI
0,36 %
0,51 %
0,64 %
0,70 %
1,43 %
1,95 %
2,01 %
2,18 %
2,62 %
3,94 %
4,88 %
6,02 %
6,87 %
7,36 %
7,86 %
7,96 %
2
110009474
42